Article No. 085110

    MB 1K rapid

    Single-component, multi-functional building waterproofing

    Product specifications

    On delivery

    Base Polymer binder, additives, special fillers
    Consistency Paste-like
    Crack-bridging ≥ 3 mm (at a dry layer thickness ≥ 3 mm)
    Layer thickness 1.3 mm wet layer thickness yields approx. 1 mm dry layer thickness
    Cross-slit pressure tests Passed, including without reinforcement fabric
    Water vapour diffusion resistance coefficient µ 9680
    Drying time Approx. 8 h at 2.5 mm wet layer thickness (20 °C/65% RH)
    Ready to be covered After approx. 72 h after application of the last layer
    Density Approx. 1.05 kg/dm³

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • For use outdoors
    • Waterproofing in new buildings
    • Can be applied > 3 m in the ground
    • Connection to water-impermeable concrete structures
    • Cross-sectional waterproofing in and under walls
    • Wall base and render waterproofing
    • Subsequent exterior waterproofing in existing buildings
    • Bonding layer on old bitumen coatings

    Properties

    • Solvent-free
    • Can be applied directly from the container without mixing
    • Fast, crosslinker-assisted complete drying
    • Rapid bond adhesion, even on non-mineral substrates
    • Very low emissions (GEV-EMICODE EC 1Plus)
    • Radon-tight (verified through testing)
    • Highly flexible, elastic and crack-bridging
    • Water pressure tight
    • Can be plastered and painted over
    • Can be applied as a slurry, with a brush or trowel, or by spraying
    • Freeze/thaw-resistant
    • Preparation
      • Substrate requirements

        The substrate must be clean, dry, flat and capable of bearing a load, and free of dust, oil, grease and release agents.

        Roughen non-mineral and pore-free substrates.

        Absorbent mineral substrates, not self-compacting concrete (SCC), may be slightly damp.

      • Preparations

        Remove projecting seams and mortar remains.

        Break off or chamfer corners and edges.

        Produce the sealing cove with a suitable mortar.

        Seal off indentations > 5 mm using a suitable filling knife.

        Roughen the surface of plastic pipes with sandpaper; clean and, if necessary, sand metal pipes.

        If necessary, provide damp proofing.

        Prime absorbent mineral substrates with Kiesol MB.

        Create a scratch coat using the product as a contact layer and in order to prevent blisters.

    • Application
      • Application temperature: min. 5 °C max. 35 °C
      • By brush / Mortar cover / Trowel application / Spraying
      • Vertical/horizontal surface waterproofing, and waterproofing in and under walls:

        Apply the product in two layers on the previously prepared substrate.

        Pipes passing through walls

        W1-E: seal pipe penetrations by using the product to form a cove around them.

        Wall base render

        A thin layer of bonding and reinforcing mortar can be applied over the top.

        Embed the reinforcing fabric in the top third of the plaster.

        Coating

        Direct coating with binder-rich dispersion coats.

        Always set up a trial area/trial areas first.

    • Application instructions
      • During application, the surface temperature of the substrate must be > 3 kelvin above the dew point temperature of the surrounding air.

        In the case of liquid-applied waterproofing materials, direct sunlight and/or wind exposure can cause accelerated skin formation and accompanying blistering.

        Do not use in direct sunlight.

        The scratch layer does not as a rule count as a waterproofing layer.

        Protect the fresh waterproofing layer from rain, direct sunlight, frost and condensation water.

        Once dry, protect from mechanical damage.

        Add a further load-distributing layer if using the product for waterproofing under raised floor supports.

        Ensure sufficient ventilation when applying the product in closed areas (wear respiratory protection if necessary).

        Please contact Remmers Technical Service (phone +49 5432 83900) before applying with machine processing.

        The maximum wet layer thickness must not exceed 4 mm.

        The formation/sealing of internal corners without a sealing cove has not been tested by the building authorities.

        Type I joints, in which joint tapes made of plastic or elastomer membranes with fleece or fabric lamination are to be embedded in the waterproofing, can only be executed with two-component liquid-applied waterproofing materials (FPD/MWS).

         

    • Working tools / cleaning
      • Mortar cover / Filling knife / Trowel application / Application by spraying
      • Scoop, smoothing trowel, layer thickness trowel, slurry brush, flat brush, roller

        Suitable machine technology, such as peristaltic pumps, screw pumps or airless piston pumps

        Clean tools with water while the material is still fresh.

        Any material that has already begun to dry can only be removed mechanically.

    • Storage / shelf life
      • Store frost-free and cool / protect for moisture / close containers
      • Shelf-life 9 months
      • If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 9 months.

    • Usage
      • 1.3 kg / mm thick layer / m²
      • Min. 1.3 kg/m²/mm dry layer thickness

        Layer thickness and application rate for interior and exterior use: see application rate table under Application Examples.

      • Apply to a large enough trial area to determine the precise amount required.

    • Application examples

      • Water impact classes
        (DIN 18533 / 18535)


        Dry layer thickness (mm)
        Wet layer thickness (mm) ****

        Application rate (kg/m²) 


        Yield 25 kg (m²)
        W1-E* 
        Ground moisture and non-pressing water
        ≥ 2
        approx. 2.6
        approx. 2.7

        approx. 9.25

        W2.1-E** 

        Moderate impact of pressing water ≤ 3 m immersion depth
        ≥ 3

        approx. 3.9

        approx. 4.0

        approx. 6.25

        W2.1-E**

        Transition to components made from water-impermeable concrete

        Moderate impact of pressing water ≤ 3 m immersion depth
        ≥ 4
        approx. 5.3
        approx. 5.5
        approx. 4.5

        W2.2-E*** 

        High impact of pressing water > 3 m immersion depth
        ≥ 4
        approx. 5.3

        approx. 5.5

        approx. 4.5

        W4-E

         

        Splashing water and ground moisture at the wall base, and capillary water in and under walls

        ≥ 2

        approx. 2.6

        approx. 2.7
        approx. 9.25
        W2-B 
        Water loads in tanks with fill level ≤ 10 m
        ≥ 3
        approx. 3.9
        approx. 4.0

        approx. 6.25



        *     Special agreement required for use on masonry
        **   Special agreement required
        *** Special agreement required - only permitted on concrete substrates up to 10 m immersion depth
        **** The maximum total wet layer thickness must not be exceeded including when applied in two layers (wet on wet). 

        Layer thickness allowance as per DIN 18533:
        The German standard prescribes a layer thickness allowance dz to ensure the minimum dry layer thickness dmin. This accounts for application-related fluctuations dv as well as the additional material needed to level out the substrate du. If the substrate is levelled separately (e.g. with a scratch coat), du is eliminated from the calculation.
        du = scratch coat, application rate approx. 0.5 kg/m² (depending on the substrate)
        dv = not required with layer thickness trowel / application rate without layer thickness trowel approx. 0.4 kg/m² (dmin = 3 mm)

    • General information
      • The characteristic data of the product were calculated under laboratory conditions at 20°C and 65% relative humidity.

        Current regulations and legal requirements must be taken into account and deviations from these must be agreed separately.

        Certificates of suitability (abP) must be observed during planning and execution.

        Special agreements and certificates of suitability can be downloaded online at www.remmers.com.

        Always set up a trial area/trial areas first.

        The material is UV-resistant on vertical surfaces in the wall base area and can also be used without a coat of paint/plaster applied in areas without ground contact.
        A change in colour is possible, but has no impact on the waterproofing function.

        Peel tests are neither suitable nor authorised for assessing the suitability of the product for use.

    • Disposal instructions
      • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.

    • Safety / regulations
      • For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.