Article No. 016401

    iQ-Therm 2.0 K 50

    Wedge-shaped interior insulation panel in the iQ-Therm 2.0 system

    Dimensions (length x breadth)
    approx. 1200 mm x 600 mm, thickness approx. 50/10 mm
    Variant
    0164 | iQ-Therm 2.0 K 50
    Size / Quantity

    Product specifications

    On delivery

    Fire class E according to DIN EN 13501-1
    Building material class B2 normal flammability according to DIN 4102-1
    Dry density > 30 kg/m³

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • Energy efficiency upgrades
    • Mould control and prevention in existing buildings
    • Implementation of the hygienic minimum heat insulation level in existing buildings
    • Improving the room climate by increasing the wall surface temperature
    • Compensation of thermal bridging effects in ceiling and wall connection areas
    • Optical correction of butt joints

    Properties

    • Excellent thermal insulation
    • Thermal conductivity (nominal value) approx. 0.028 W/(m•K)
    • Low construction height
    • Easy to apply
    • Thermal insulation material according to DIN 4108-10
    • Preparation
      • Substrate requirements

        The substrate must be load-bearing, even, clean, dry and free from adhesion-reducing substances.

      • Preparations

        Level off and even out highly uneven substrates – use SP Level to close up joints and even out surfaces.

    • Application
      • Application temperature: min. 5 °C
      • Jigsaw / Cutter
      • Pre-wet the substrate.

        Apply iQ M universal to the substrate as a scratch coat.

        Use a notched trowel to apply iQ M universal wet-on-wet to the back of the wedge and the substrate.

        Position and press on the boards from the bottom up.

        Align using a floating rule.

    • Application instructions
      • Mark the desired dimensions on the board.

        Cut to size using a cutter knife.

        Rework the cut edges with a rasp or file if necessary.

        Avoid cross joints.

        Align using a floating rule.

        Make sure that full-surface bonding is achieved.

    • Working tools / cleaning
      • Jigsaw / Cutter
      • Cutter knife

    • Storage / shelf life
      • Store frost-free / close containers
      • Dry and frost-free.

    • Usage
      • 1.4 panels / m²
      • Approx. 1.4 panels/m²

    • General information
      • Current regulations and legal requirements must be taken into account and deviations from these must be agreed separately.