PCC I (RM) concrete replacement mortar for static repair of concrete structures
Product specifications
On delivery
28 days: 12 N/mm²
28 days: 55 N/mm²
The stated values represent typical product characteristics and are not to be construed as binding product specifications.
Field of application
- Concrete replacement for structurally relevant repairs
- Concrete substitution according to
- DIN EN 1504-3
- DIN 19573
Properties
- High sulphate resistance
- High mechanical resistance
- High resistance to water penetration
- Very low shrinkage
- Can be applied by machine
- Freeze/thaw-resistant
-
Preparation
-
Substrate requirements
Concrete surface:
Stable, clean, dust-free
Observe the applicable technical regulations for the following parameters:
- Adhesive pull strength of the substrate
- Minimum roughness/roughness depthPre-wet the substrate so that it is slightly moist.
-
Preparations
Reinforcement:
Degree of purity SA 2 ½ if applying corrosion protection, otherwise SA 2
-
-
Application
-
Working time
(+20 °C): Approx. 60 minutesLayer thickness
Single layer 12 mm to 50 mm
A bonding layer is required when applying manually.
Apply wet-on-wet.
Subsequent processing
Protect fresh mortar surfaces from wind, direct sunlight, rain and/or frost for at least 3 days so that they do not dry too quickly.
Machine working
Please contact Remmers Technical Service (phone +49 5432 83900) before applying with machine processing.
-
Working tools / cleaning
-
Mixing tool, trowel, aluminium rule, smoothing trowel, power trowel
Clean tools with water while the material is still fresh.
-
Storage / shelf life
-
If stored in an unopened container and in a dry place, the product will keep for approx. 12 months.
-
Usage
-
Approx. 2.0 kg/m²/mm layer thickness or 2.0 kg/dm³
-
Disposal instructions
-
Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.
-
-
Safety / regulations
-
For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.
-