• Betonhaut

    Article No. 123030

    Betofix NBM

    Curing agent for concrete

    Product specifications

    On delivery

    Density (20°C) 1.00 g/cm³
    Colour Whitish
    Consistency Liquid
    pH value Approx. 9
    Barrier coefficient SM 92%
    SRT value (grip) 64 scale divisions

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • For use on floors/walls indoors and outdoors
    • Curing agent for general concrete construction and concrete for traffic infrastructure
    • For use cases VM and BM according to TL NBM-StB 09

    Properties

    • Water-based
    • Barrier coefficient SM ≥ 85%
    • SRT value (grip) ≥ 50 scale divisions
    • Ready-to-use emulsion
    • Solvent-free
    • Sprayable
    • Forms a barrier film on the surface
    • Application instructions
      • Apply the material after the water has evaporated.

        Take appropriate measures to protect adjacent building elements and materials that should not come into contact with the product.

    • Working tools / cleaning
      • Low pressure spraying
      • Airless equipment, low-pressure sprayer

        Clean tools with water while the material is still fresh.

    • Storage / shelf life
      • Store frost-free and cool / protect for moisture / close containers
      • Shelf-life 6 months
      • If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 6 months.

    • Usage
      • Approx. 150 ml/m²

    • Application examples
      • Use cases VM and BM pursuant to Technical Guideline NBM-StB 09Time of application
        slightly damp
        M
        Concrete for traffic areas (road concrete with grip requirements applicable to the surface)VVM
        General concrete construction (concrete for building elements that are not driven over and with no grip requirements)BBM

    • General information
      • Not suitable for intermediate post-treatment.

        Remove all material residue from the concrete surface before applying any coatings.

        Current regulations and legal requirements must be taken into account and deviations from these must be agreed separately.

        The relevant test certificates must be observed when planning and carrying out work.

    • Disposal instructions
      • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.

    • Safety / regulations
      • For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.