• Induline ZW-507i
  • Induline ZW-507i
    • Induline ZW-507i
    • Induline ZW-507i

    Article No. 163620

    Induline ZW-507i

    Water-based, transparent sealing filler for spraying methods

    Colour: clear | 1636

    Product specifications

    On delivery

    Binder Acrylate/PU copolymer
    Density (20°C) Approx. 1.03 g/cm³
    Odour Characteristic
    Viscosity Ca. 2600 mPas

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • For use indoors and outdoors
    • for exterior doors
    • For professional users only
    • For use on interior and exterior wood
    • Softwood and hardwood (in particular larch and oak)
    • Dimensionally stable wood building elements: e.g. windows and doors
    • Intermediate coat for opaque and transparent systems

    Properties

    • Water-based
    • Good flow properties
    • Outstanding (wet) adhesion
    • Less discolouration due to water-soluble substances in the wood
    • Reduces surface impairments caused by substances contained in specific types of wood (e.g. larch).
    • Reduces the tendency of the wood to turn darker as a result of a reaction to tannic acid (e.g. oak)
    • UV blockers provide greater protection for translucent colours
    • Good sanding properties
    • Preparation
      • Substrate requirements

        The substrate must be clean, dry, free of dust, grease and loose substances, and prepared in the correct manner.

        Dimensionally stable wood building elements: wood moisture content 11-15%

      • Preparations

        If necessary, impregnate non-resistant woods with a wood preservative* (*Use biocides safely. Always read the label and product information before use).

        Prime wood surfaces.

        If necessary, protect parapet joints with Induline V-Joint Protection or Induline AF-920.

    • Application
      • Temperature of the material, air and substrate: from min. +15 °C to max. +30 °C
      • Stir before use
      • Spraying only in closed facilities
      • Airless/airmix spraying
      • Dynflow (fully automatic coating plant)
      • The values given are based on undiluted material. The best spraying pattern is achieved if the material has a temperature of 15-20 °C.

        Ensure good ventilation.

        If necessary, check compatibility with the substrate and sealing effect by applying a trial coat.

        Airless spraying: nozzle size: 0.28-0.33 mm; material pressure: 90-120 bar.

        Air-mix spraying: nozzle size: 0.28-0.33 mm; material pressure: 70-90 bar, atomiser air pressure 1-2 bar.

        A repeat application may be required in exceptional cases.

        Carry out intermediate sanding before applying a final coat: P 220-240, remove sanding dust.

        Seal opened containers well and use contents as soon as possible.

    • Application instructions
      • Drying time: can be worked over after 4 h
      • Check colour, adhesion and compatibility with the substrate by setting up a trial area.

        Before coating technically modified woods and wood-based materials, apply the product to a trial surface and conduct a suitability test on the desired area of use.

        Prior to full application, please apply a test coat to a sample area under practical conditions using the desired system, then test or examine the surface properties.

        With water based coating systems, there is always a residual risk that substances contained in the wood will cause discolouration.

        Bleeding resin is a natural phenomenon and cannot be prevented by coating measures, see BFS Code of Practice No. 18.

        The product's sealing effect may be impaired if it is diluted too thinly, if the wood is too wet or if the recommended coating sequence, application volumes and drying times are not observed.

        In the case of porous wood types (e.g. oak), care must be taken to ensure that the varnish fills the pores. It may be necessary to exceed the recommended application quantity.

        Observe current standards and guidelines for coating wood building elements outdoors (Codes of Practice issued by the German Association of Window and Facade Manufacturers (VFF), Code of Practice No. 18 issued by the German Federal Committee for Paint and the Protection of Material Assets (BFS), guidelines issued by the German Lacquer and Printing Ink Association (VdL) and ift guidelines issued by the Institut für Fenstertechnik).

        The system finder on our website www.remmers.com contains coating recommendations for specific wood types to be used when treating windows and exterior doors.

      • Drying

        Dust dry: after approx. 1 hour
        Sandable and recoatable: after approx. 4 hours
        (at 23 °C and 50% RH)

        Sandable and recoatable with forced drying: after approx. 20 minutes flash-off zone (at approx. 20 °C and 65 - 75% RH) / 75 minutes drying phase (approx. 45 °C, 1 m/s air circulation) / 20 minutes cooling phase

        Low temperatures, poor ventilation and high humidity delay drying.

      • Thinning

        Dilute with water if necessary (max. 5%).

    • Working tools / cleaning
      • Spraying only in closed facilities
      • Airless/airmix spraying
      • Dynflow (fully automatic coating plant)
      • Spraying systems, manual spray gun, Dynflow system

      • Clean tools with water or Aqua RK-898 Cleaning Concentrate immediately after use.

        Ensure that any residue from cleaning is disposed of correctly.

    • Storage / shelf life
      • Store frost-free and cool / protect for moisture / close containers
      • Shelf-life 12 months
      • If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.

    • Usage
      • Approx. 150 ml - 200 ml / m² per layer applied
      • 150 - 200 ml/m² per coat
        (equivalent to: wet film thickness: 150 - 200 µm, dry film thickness: 35 - 45 µm)

    • General information
      • Sealing compounds must be compatible with the coating and may only be applied once the coating has dried thoroughly.

        Only use sealing profiles that are free of plasticisers.

    • Disposal instructions
      • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.

    • Safety / regulations
      • For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.