Article No. 510505
Water-based, cloth matt, transparent coating for wood/aluminium constructions
Product specifications
On delivery
The stated values represent typical product characteristics and are not to be construed as binding product specifications.
Field of application
- Soft and hard woods
- Dimensionally stable wood/aluminium building elements: e.g. wood/aluminium windows and doors
- Not suitable for exterior surfaces of dimensionally stable wood building elements that are exposed to weather conditions
- Intermediate and finishing coats
- Single coat and multi-coat procedure
Properties
- Good flow properties
- Block resistant (in accordance with Code of Practice HO.03)
- UV-resistant and colourfast
- Reduces grain emphasis and yellowing of wood substrate
- Natural look and feel
-
Preparation
-
Substrate requirements
The substrate must be clean, dry, free of dust, grease and loose substances, and prepared in the correct manner.
Dimensionally stable wood building elements: wood moisture content 11-15%
-
Preparations
If necessary, impregnate non-resistant woods with a wood preservative* (*Use biocides safely. Always read the label and product information before use).
Pre-treat using a suitable primer & intermediate coat and carry out intermediate sanding if necessary.
If necessary, protect parapet joints with Induline V-Joint Protection or Induline AF-920.
-
-
Application
-
The values given are based on undiluted material. The best spraying pattern is achieved if the material has a temperature of 15-20 °C.
Ensure good ventilation.
Airless spraying: nozzle size: 0.28-0.33 mm; material pressure: 90-120 bar.
Air-mix spraying: nozzle size: 0.28-0.33 mm; material pressure: 70-90 bar, atomiser air pressure 1-2 bar.
Seal opened containers well and use contents as soon as possible.
-
Application instructions
-
Check colour, adhesion and compatibility with the substrate by setting up a trial area.
Before coating technically modified woods and wood-based materials, apply the product to a trial surface and conduct a suitability test on the desired area of use.
Prior to full application, please apply a test coat to a sample area under practical conditions using the desired system, then test or examine the surface properties.
Do not use in direct sunlight or at temperatures below +15 °C or above +30 °C.
Substances in oak may bleed, causing dark discolouration, when coated with water dilutable dispersion stains.
To prevent any substances in the wood from becoming active, forced drying should be carried out.
The system finder on our website www.remmers.com contains coating recommendations for specific wood types to be used when treating windows and exterior doors.
-
Drying
Dust dry: after approx. 1 hour
Ready for sanding and next coat: after approx. 4 hours
If forced drying is used, ready for sanding and next coat: after approx. 20 minutes flash-off zone (at approx. 20 °C and 65 - 75% RH) / 75 minutes drying phase (approx. 45°C, 1 m/s air circulation) / 20 minutes cooling phasePractice values at +20 °C and 65% relative humidity.
Low temperatures, poor ventilation and high humidity delay drying.
-
Thinning
If thinning is necessary, use water (max. 5%)
-
Working tools / cleaning
-
Manual spray gun, automatic sprayer.
-
Clean tools with water or Aqua RK-898 Cleaning Concentrate immediately after use.
Ensure that any residue from cleaning is disposed of correctly.
-
Storage / shelf life
-
If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.
-
Usage
-
125 - 225 ml/m² (plus spraying loss)
(corresponds to wet film thickness: 125-225 µm, dry film thickness: 40-80 µm)
-
General information
-
Sealing compounds must be compatible with the coating and may only be applied once the coating has dried thoroughly.
Only use sealing profiles that are free of plasticisers.
This product can be used with Induline Perfect Finish to obtain a varnish in brushing consistency for restoring and patching up.
For cleaning and care, we recommend the care set for windows (2745)
Observe current standards and guidelines for coating wood building elements outdoors (Codes of Practice issued by the German Association of Window and Facade Manufacturers (VFF), Code of Practice No. 18 issued by the German Federal Committee for Paint and the Protection of Material Assets (BFS), guidelines issued by the German Lacquer and Printing Ink Association (VdL) and ift guidelines issued by the Institut für Fenstertechnik).
-
-
Disposal instructions
-
Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.
-
-
Safety / regulations
-
For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.
-