• Funcosil FC pro

    Article No. 070313

    Funcosil FC pro

    Silane-based impregnation cream for hydrophobic treatment adapted to specific substrates

    Variant
    0703 | Funcosil FC pro
    Size / Quantity

    Product specifications

    On delivery

    Appearance Milky, white, creamy
    Density (20°C) Approx. 0.82-0.90 depending on the formulation
    Flash point > 61
    Active ingredient Silane/siloxane
    Active ingredient content, % by mass Adjusted for the specific building following preliminary examination
    Carrier material Dearomatized hydrocarbons/water

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • For use outdoors
    • Adaptive protection of facades against driving rain
    • Reduces susceptibility to dirt and green discolouration
    • Porous, mineral building materials such as fired and sand-lime brick, clinker and render
    • Supplementary measure as part of energy-efficient renovation work, particularly in conjunction with the capillary-active insulation of interior walls
    • Adaptive reduction in capillary water absorption for specific buildings in order to guarantee high redrying potential (preliminary examination required)

    Properties

    • Adapted to reduce capillary transport
    • Enables water vapour diffusion
    • Outstanding penetration
    • UV-resistant
    • Alkali-resistant
    • Excellent long-term effect
    • Can be applied sparingly, with absolute precision and with no losses
    • Preparation
      • Substrate requirements

        The substrate must be clean, dust-free and dry.

      • Preparations

        Any construction defects such as cracks, cracked joints, defective connections, rising damp and hygroscopic moisture must be remedied in advance.

        Perform any necessary cleaning gently, e.g. by spraying with cold or warm water or by steam-cleaning; use rotec soft whirl jet technology or Remmers cleaning products (e.g. Traffic Film Remover (0671), Clean FP (0666), Clean AC (0672), Combi WR (0675)) on tough stains.

    • Application
      • Application temperature: min. 10 °C max. 25 °C
      • By brush / By roller / Airless/airmix spraying
      • Apply the impregnation agent with a suitable tool, working crosswise, or by airless spraying.

    • Application instructions
      • Take appropriate measures to protect adjacent building elements and materials that should not come into contact with the product.

        Protect freshly treated surfaces from driving rain, wind, sunlight and condensation.

        Remove any excess impregnation agent within 1 hour using V 101 thinner.

    • Working tools / cleaning
      • By brush / By roller / Airless/airmix spraying
      • Long-pile lambskin roller, brush.
        Airless nozzles: 40° spraying angle, 0.021-inch drilled hole, max. 60 bar spraying pressure

      • Tools must be clean and dry.

        Clean tools with water after use and before any lengthy interruptions to work.

    • Storage / shelf life
      • Store frost-free and cool / protect for moisture / close containers
      • Shelf-life 12 months
      • If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.

        Use the contents of open containers as quickly as possible.

    • Usage
      • Total application/absorption rate 150 ml - 200 ml Total / m²
      • In a single coat, depending on porosity: approx. 0.15 - 0.20 l/m²

      • Apply to a large enough trial surface (1-2 m²) to determine the precise amount of impregnation agent required.

    • General information
      • Current regulations and legal requirements must be taken into account and deviations from these must be agreed separately.

        The relevant test certificates must be observed when planning and carrying out work.

        Water must not be allowed to penetrate behind the hydrophobized zone.

        Carry out a quantitative analysis of aggressive salts if there are any salts present that could damage building materials.

        High concentrations of harmful salts can cause major structural damage that impregnation cannot prevent.

        The level of absorption is crucial for the impregnation agent to work at its best. This depends on the respective pore volume and moisture content of the building material.

        Testing effectiveness:


        The water absorption of mineral building materials can be determined using the Funcosil Test Tube developed by Professor Karsten (Funcosil Facade Testing Kit, article no. 4954).

        Testing can only be carried out at the earliest 6 weeks after application.

        Substrates with very low absorbency and highly textured surfaces should be treated with a liquid impregnation agent.

        A test of effectiveness needs to be carried out on carbonaceous natural stone.

        Always set up a trial area/trial areas first.

    • Disposal instructions
      • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.

    Systemproducts