Article No. 061113
Silane-based impregnation in cream form with limited capillary inhibition
Product specifications
On delivery
The stated values represent typical product characteristics and are not to be construed as binding product specifications.
Field of application
- Driving rain protection for monuments and listed buildings
- Mineral building materials such as render, brick and natural stone
- Reduction in capillary water uptake while preserving residual capillarity
Properties
- Reduces the w-value
- Enables water vapour diffusion
- No water repelling effect
- Outstanding penetration
- UV-resistant
- Alkali-resistant
- With a mineral water base
- Can be applied sparingly, with absolute precision and with no losses
-
Preparation
-
Substrate requirements
The substrate must be clean, dust-free and dry.
-
Preparations
Any construction defects such as cracks, cracked joints, defective connections, rising damp and hygroscopic moisture must be remedied in advance.
Perform any necessary cleaning gently, e.g. by spraying with cold or warm water or by steam-cleaning; use rotec soft whirl jet technology or Remmers cleaning products (e.g. Traffic Film Remover (0671), Clean FP (0666), Clean AC (0672), Combi WR (0675)) on tough stains.
-
-
Application
-
Apply the impregnation agent with a suitable tool, working crosswise, or by airless spraying.
-
Application instructions
-
Take appropriate measures to protect adjacent building elements and materials that should not come into contact with the product.
Protect freshly treated surfaces from driving rain, wind, sunlight and condensation.
Remove any excess impregnation agent within 1 hour using V 101 thinner.
-
-
Working tools / cleaning
-
Long-pile lamb's wool roller, brush.
Airless nozzle: 40° spraying angle, bore hole 0.021 inches, max. 60 bar spraying pressure -
Tools must be clean and dry.
Clean tools with water after use and before any lengthy interruptions to work.
-
Storage / shelf life
-
If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.
Use the contents of open containers as quickly as possible.
-
Usage
-
Depending on the porosity, in one coat: approx. 0.15 - 0.20 l/m²
-
Apply to a large enough trial surface (1-2 m²) to determine the precise amount of impregnation agent required.
-
General information
-
Current regulations and legal requirements must be taken into account and deviations from these must be agreed separately.
The relevant test certificates must be observed when planning and carrying out work.
Carry out a quantitative analysis of aggressive salts if there are any salts present that could damage building materials.
High concentrations of harmful salts can cause major structural damage that impregnation cannot prevent.
The level of absorption is crucial for the impregnation agent to work at its best. This depends on the respective pore volume and moisture content of the building material.
Testing effectiveness:
The water absorption of mineral building materials can be determined using the Funcosil Test Tube developed by Professor Karsten (Funcosil Facade Testing Kit, article no. 4954).
Testing can only be carried out at the earliest 6 weeks after application.A test of effectiveness needs to be carried out on carbonaceous natural stone.
Always set up a trial area/trial areas first.
-
-
Disposal instructions
-
Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.
-