Article No. 28121005
Water-based, translucent 2K finishing coat for durable and aesthetic windows and doors, for spray application
Downloads & documents
Product specifications
On delivery
The stated values represent typical product characteristics and are not to be construed as binding product specifications.
Field of application
- For use on interior and exterior wood
- Soft and hard woods
- Dimensionally stable wood building elements: e.g. doors, windows and shutters
Properties
- Excellent flow properties
- Outstanding (wet) adhesion
- High level of UV resistance and colour stability
- Resistant to yellowing
- High brilliance
- Increased block resistance
- Very high scratch resistance
- Good resistance to chemicals
- Good resistance to a wide range of commercially available hand creams
- Weather resistant
- Good hail resistance
- Compatible with the Induline coating system
-
Preparation
-
Substrate requirements
The substrate must be clean, dry, free of dust, grease and loose substances, and prepared in the correct manner.
Dimensionally stable wood building elements: wood moisture content 11-15%
-
Preparations
If necessary, impregnate non-resistant woods with a wood preservative* (*Use biocides safely. Always read the label and product information before use).
Pre-treat using a suitable primer & intermediate coat and carry out intermediate sanding if necessary.
If necessary, protect parapet joints with Induline V-Joint Protection or Induline AF-920.
-
-
Application
-
The values given are based on undiluted material. The best spraying pattern is achieved if the material has a temperature of 15-20 °C.
Airless spraying: Nozzle: 0.28 mm, spraying pressure: 120 - 130 bar
Airmix spraying: Nozzle: 0.28 mm, spraying pressure: 100 - 120 bar, air pressure 1.4 - 1.6 bar
Flow cup gun: Nozzle: 2.0 - 2.5 mm, atomiser air pressure: 3.0 - 4.0 bar.
Seal opened containers well and use contents as soon as possible.
-
Application instructions
-
Check colour, adhesion and compatibility with the substrate by setting up a trial area.
Before coating technically modified woods and wood-based materials, apply the product to a trial surface and conduct a suitability test on the desired area of use.
Ensure good ventilation.
Do not use in direct sunlight or at temperatures below +15 °C or above +30 °C.
Substances in oak may bleed, causing dark discolouration, when coated with water dilutable dispersion stains.
The clear colour version of the product is not suited for use on exterior surfaces that are directly exposed to weather.
-
Drying
Dust-dry: after approx. 1 hour
Ready for sanding and overcoating: after approx. 4 hours (at 23 °C and 50% RH)If the temperature goes below the specified working temperature or exceeds the specified atmospheric humidity or maximum coat thickness, this will delay full drying and lead to inclusion of hydrophilic emulsifiers. This increases the risk of temporary water staining. This effect is reduced as the coat continues to harden.
-
Thinning
Ready to use, dilute with max. 10% water if necessary.
Application with flow cup gun: dilute with 10 - 20% water.
-
Working tools / cleaning
-
Airless/Airmix spraying equipment, flow cup gun
-
Clean tools immediately after use with HFW7-017A special cleaning solution.
Ensure that any residue from cleaning is disposed of correctly.
-
Storage / shelf life
-
If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.
-
Usage
-
Approx. 175 ml/m² (plus spraying loss)
(equivalent to a wet film thickness of approx. 175 µm and a dry film thickness of approx. 65 µm)
-
General information
-
Sealing:
Sealing compounds must be compatible with the coating and may only be applied once the coating has dried thoroughly.
Only use sealing profiles that are free of plasticisers.
Care and maintenance:
Wood is subjected to great climatic and environmental stresses when outdoors. The coat is susceptible to the processes of natural ageing, wear and decomposition. Decomposition takes place at different speeds, depending on the stress (weak, average, strong) placed on the wood building element. Weathering stages may vary according to the part or element affected. To give wood the longest and best possible protection it is advisable to examine surfaces every year. Any damage found should be addressed immediately after cleaning.
For cleaning and care, we recommend the care set for windows (2745) and doors (2746).
Use Aqua HSL-35 and Aqua DSL-55 or HSL-30 and MSL-40 to carry out repairs.
-
-
Disposal instructions
-
Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.
-
-
Safety / regulations
-
For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.
-