Solvent-based wood preservative with preventive action against blue stain, rot & insects
Downloads & documents
Safety instructions
- Use biocides safely. Always read the label and product information before using!
Product specifications
On delivery
The stated values represent typical product characteristics and are not to be construed as binding product specifications.
Field of application
- For use on exterior wood
- Wood which is not in ground contact, in accordance with DIN EN 335-1, use classes 2 and 3
- Wood building elements with no dimensional stability: e.g. fences, framework, carports, planking
- Wood building elements with limited dimensional stability, e.g. folding shutters, matchboarding, summerhouses
- Load-bearing wood elements under roofs (e.g. trusses)
- Dimensionally stable wood building elements (when used as a primer only): e.g. windows and doors
- Pre-treatment under translucent or opaque coatings
Properties
- Preventive protection against wood-discolouring fungi (blue stain), wood-destroying fungi (rot) & insects
- Resistant to swelling, regulates moisture
- Impregnated wood is suitable for all follow-up coatings
-
Preparation
-
Substrate requirements
The substrate must be clean, dust-free and dry.
Dimensionally stable wood building elements: wood moisture content 11-15%
Wood building elements with limited or no dimensional stability: wood moisture content max. 18%
-
Preparations
Thoroughly remove any dirt, grease and non-adhering old coatings.
Take appropriate measures to protect adjacent building elements and materials that should not come into contact with the product.
Observe BFS Code of Practice No. 18 "Coatings on Wood and Wooden Working Materials in Outdoor Areas".
-
-
Application
-
Stir well.
Qualified specialist companies: brushing, dipping, flow-coating and spraying in closed systems only.
Seal opened containers well and use contents as soon as possible.
-
Application instructions
-
Check colour, adhesion and compatibility with the substrate by setting up a trial area.
-
Drying
Practice values at +20 °C and 65% relative humidity.
Low temperatures, poor ventilation and high humidity delay drying.
After drying, the treated wood can be finished with acwater-based or solvent-based coating system.
If a water-based finish is used, overnight drying is required.
-
Working tools / cleaning
-
Brush with natural bristles, flat brush, dipping tank, spraying tunnel
-
Clean tools immediately after use with V 101 Thinner.
Dispose of the remains from cleaning properly.
-
Storage / shelf life
-
Store in well-sealed, original containers, out of the reach of children and in a dry, cool, well-ventilated room which is protected from direct sunlight and frost. No smoking is permitted in storage areas.
-
Usage
-
Softwood: 160 ml/m² or 130 g/m²
Hardwood: 225 ml/m² or 180 g/m²
Brushing/rolling in 2-3 coats
Automatic and manual dipping, spray tunnel method in 1-2 coats
-
-
General information
-
According to the current state of the art (this includes DIN 68800-1 and -3 in Germany), wood preservation measures must also be planned for non-load-bearing wooden elements in good time and with due care, with the agreement of all parties involved in the construction (architect, developer, builder) and in compliance with the legal requirements and the conditions on site. The use of biocidal (“chemical”) wood preservatives should therefore always be indicated in suitable fashion prior to sale, or must be agreed in advance with the client in writing. Failure to comply with this requirement may result in country-specific or contract-specific conflicts with legal requirements, standards or certification systems. The Remmers Technical Service would be happy to discuss the matter and provide you with a template agreement for the use of a biocidal (“chemical”) wood preservative on the wooden elements being used.
-
-
Disposal instructions
-
Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.
-
-
Safety / regulations
-
For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.
-