Article No. 606211
Solvent-based adhesion promoter
Product specifications
On delivery
Component A
Component B
Mixture
The stated values represent typical product characteristics and are not to be construed as binding product specifications.
Field of application
- Adhesion promoter on floating and sealing layers in Remmers Deck systems
- Only suitable for outdoor applications
Properties
- Moisture-curing
- Contains solvents
- Two-component
- Blue, translucent
-
Preparation
-
Substrate requirements
The substrate must be dry.
Suitable for use as a substrate on floating and sealing layers in Remmers Deck systems.
The substrate must be firm, dimensionally stable, capable of bearing loads and free of loose constituents, dust, oil, grease, rubber marks and other substances that could interfere with adhesion.
The surface of the floating and sealing layer must not be allowed to chalk or crackle.
Surfaces for which the time window for overcoating has been exceeded, or which have been exposed to moisture during this period, e.g. due to dew or rain, must be sanded down to the point of white breakage and then thoroughly cleaned before applying PUR Primer S 2K. Disc sanders fitted with suitable sanding pads may be used for sanding. (see Remmers installation instructions for the reactivation of fully cured floating and sealing layers)
-
-
Working tools / cleaning
-
Microfibre roller, paintbrush, mixing device
-
More detailed information can be found in the Remmers Tool Programme.
Clean tools and remove any contamination immediately after use and while fresh using Thinner V 103.
Take suitable protective and waste disposal measures when cleaning.
-
Storage / shelf life
-
If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.
-
Usage
-
Max. 0.05 kg/m² (depending on the substrate)
-
-
Application examples
-
Priming
Using a microfibre roller, apply a thin, even layer of adhesion promoter crosswise.
max. 0.05 kg/m²
-
Roller coating
-
-
General information
-
Unless otherwise specified, all of the values and application rates given above have been determined under laboratory conditions (20 °C) using standard colours. Slight deviations from these values may arise if the product is worked with on site.
The product cures under the influence of humidity. If the layers are too thick, foam may form.
Do not use on old (more than 2 days old) or superficially damaged surfaces (e.g. crackling or heavy chalking).
The substrate must be protected against direct water loads before, during and after coating. If this is not done, the surface must be sanded down again and cleaned, and the adhesion promoter must be applied again.
Further notes on working, system construction and maintenance of the listed products can be found in the latest Technical Data Sheets and the Remmers system recommendations.
-
-
Disposal instructions
-
Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not pour liquid coating or residues down the drain, even when cleaning tools used for applying the coating.
-
-
Safety / regulations
-
For professional users only!
Further information concerning safety during transport, storage and handling as well as on disposal and ecology can be found in the latest Safety Data Sheet.
-