Article No. 764106
Self-levelling, 2-component joint sealing compound on a synthetic resin/polyurethane base
Product specifications
On delivery
Once fully cured
(DIN EN ISO 7389) > 90%
(DIN EN ISO 10563) -3%
The stated values represent typical product characteristics and are not to be construed as binding product specifications.
Field of application
- Elastic filling of floor joints in paved areas and on screeds in parking garages, underground garages, factory halls, walkways and terraces
Properties
- Resistant to water, sewage, salt water, weak acids, lyes, oils and most solvents
- Resistant to diluted acids and alkalis
- Resistant to fuel and oils
-
Preparation
-
Substrate requirements
The sides of the joints must be load-bearing, dry, clean and free of grease, metals must be bare.
-
Preparations
Prime the joint edges with a suitable Remmers Primer.
Fill deep joints with round cords.
-
-
Preparation
-
Combination container
Add the entire quantity of the hardener (component B) to the base compound (component A).
Mix thoroughly with a slow-speed electric mixer
(approx. 300 - 400 rpm).Mix for at least 3 minutes.
Insufficient mixing is indicated by streaks forming.
-
Application
-
Application requirements
Temperature of the material, air and substrate: from min. +10 °C to max. +35 °C
-
After mixing, pour the material into the joint with a pouring aid.
-
Application instructions
-
Uncontrolled material flow must be prevented by suitable measures.
The stability of the material can be increased by adding a suitable thixotropic agent (e.g. WHG TX).
Protect the material from weathering for at least 24 hours after application.
-
-
Working tools / cleaning
-
Suitable mixing device, pouring aid
Clean tools while fresh with V 101. After setting, the material can only be removed by mechanical means. If necessary, swell first with V 101.
-
-
Storage / shelf life
-
If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.
-
Usage
-
Approx. 130 g/running metre for a 1 cm² joint cross-section
-
-
General information
-
Take appropriate measures to protect adjacent building elements and materials that should not come into contact with the product.
Always set up a trial area/trial areas first.
After approx. 3 days chemically and mechanically resistant.
Bitumen intolerant.
Current regulations and legal requirements must be taken into account and deviations from these must be agreed separately.
The relevant test certificates must be observed when planning and carrying out work.
-
-
Disposal instructions
-
Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.
-
-
Safety / regulations
-
For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.
-