    Product specifications

    On delivery

    Component A

    Density (20°C) 1.12 g/cm³
    Viscosity (25 °C) 2200 mPa s

    Component B

    Density (20°C) 1.29 g/cm³
    Viscosity (25 °C) 425 mPa s

    Component C

    Density (20°C) 0.98 g/cm³
    Viscosity (25 °C) <1 mPa s

    Mixture (3C)

    Density (20°C) 1.17 g/cm³
    Viscosity (25 °C) 925 mPa s

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • For professional users only
    • Unpigmented primer underneath coatings

    Properties

    • Rapid hardening with long processing time
    • Full hardening from +3 °C
    • Saponification stable
    • Suitable for use as a primer without broadcasting underneath Remmers PU, QP and EP coatings
    • Preparation
      • Substrate requirements

        The substrate must be firm, dimensionally stable, capable of bearing loads and free of loose constituents, dust, oil, grease, rubber marks and other substances that could interfere with adhesion.

        The tensile strength of the surface of the substrate must be at least 1.5 N/mm² on average (smallest individual value of at least 1.0 N/mm²), and the compressive strength must be at least 25 N/mm².

        Concretemax. 4 m% moisture

        Cement screedmax. 4 m% moisture

        The substrate must be protected from exposure to moisture from underneath during utilisation.

      • Preparations

        Prepare the substrate by suitable means, e.g. steel ball jetting or diamond grinding, so that it meets the requirements specified above.

        Broken-out or missing areas in the substrate should be filled flush with the surface using Remmers RM systems (RM = Repair Mortar) or Remmers EP mortars.

    • Preparation
      • Mixing time 3 min
      • Combination container

        Add the entire quantity of the hardener (component B) to the base compound (component A).

        Then add all of component C (QP Primer Cat).

        Mix thoroughly with a slow-speed electric mixer
        (approx. 300 - 400 rpm).

        Mix for at least 3 minutes.

        Insufficient mixing is indicated by streaks forming.

    • Application
      • Application temperature: min. 3 °C max. 30 °C
      • By roller
      • Pot life 30 min
      • As a general principle, higher temperatures will reduce and lower temperatures will increase the times stated.

        The material can be accelerated by a further addition of QP Primer Cat (6931) (see Technical Data Sheet).

    • Working tools / cleaning
      • By roller
      • Rubber blade, epoxy roller, suitable mixing apparatus

      • More detailed information can be found in the Remmers Tool Programme.

        Clean tools, equipment and splashed material immediately while fresh with V 101.

        Take suitable protective and waste disposal measures when cleaning.

    • Storage / shelf life
      • Store frost-free
      • Shelf-life 6 months
      • If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 6 months.

    • Usage
      • See application examples

    • Application examples
      • Priming

        Apply the mixed resin generously to the surface. Distribute with a suitable tool, e.g. rubber blade, and work into the substrate with an epoxy roller so that pores in the surface of the substrate are completely filled.

        It may be necessary to apply several layers.

        approx. 0.30 - 0.50 kg/m² binder (depending on the substrate)

    • General information
      • Unless otherwise specified, all of the values and application rates given above have been determined under laboratory conditions (20 °C). Slight deviations from these values may arise if the product is worked with on site.

        Primers must always be applied so that all pores are filled; it may therefore be necessary to increase the application rate or to apply a second coat.

        Further notes on working, system construction and maintenance of the listed products can be found in the latest Technical Data Sheets and the Remmers system recommendations.

    • Disposal instructions
      • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.

    • Safety / regulations
      • For professional users only!

        Further information concerning safety during transport, storage and handling as well as on disposal and ecology can be found in the latest Safety Data Sheet.