    Product specifications

    On delivery

    Density (20°C) Approx. 1.0 g/ml

    Once fully cured

    Once fully cured

    E-modulus
    100% (DIN EN ISO 8339)
    0.40 N/mm²
    Elongation at break
    (DIN EN ISO 8339)
    > 200%
    Elastic recovery
    (DIN EN ISO 7389)
    Approx. 90%
    Volume loss
    (DIN EN ISO 10563)
    Approx. -4%

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • For use on floors/walls/ceilings indoors and outdoors
    • for wood floors
    • for dimensionally stable elements
    • Glazing work – especially in wood window manufacturing
    • Expansion and connection joints in buildings and sanitary areas
    • Waterproofing in roof areas
    • Food Production Areas
    • Metal and sheet metal processing
    • Interior construction, parquet etc.
    • Mounting of mirrors and plexiglass
    • Suitable for use in clean rooms and ventilation and air-conditioning installations

    Properties

    • Highly abrasion-resistant and streak-free according to ift guideline VE-04/2
    • Coating-compatible according to DIN 52452, part 4
    • Film preserver protects against microbial damage
    • Extremely strong adhesion
    • No need for an adhesive primer on many substrates
    • Very low emissions (GEV-EMICODE EC 1Plus)
    • Fire resistant
    • Complies with the principles for the health assessment of construction products used indoors (AgBB scheme)
    • Preparation
      • Substrate requirements

        The sides of the joints must be load-bearing, dry, clean and free of grease, metals must be bare.

      • Preparations

        For window-making, the regulations of DIN 18545 or the information publications of IFT Rosenheim must be observed.

        In construction work the joint dimensions required by DIN 18540 must be observed.

        Avoid three-sided adhesion.

        Joints that are too deep should be filled with round cords.

        If needed and depending on the substrate, Silicone Primer P can be used as an adhesive primer.

        Observe flash-off times.

    • Application
      • Application temperature: min. 5 °C max. 35 °C
      • Gun for sealing compounds
      • Filling knife
      • Cut off tip at an angle according to the width of the joint and inject, filling the joint completely.

        Apply the material with sufficient pressure to the sides of the joint, then smoothen with a moist spatula.

    • Application instructions
      • Skin formation and hardening depend on storage and change as the product ages.

        Hardening times increase at increasing joint depths.

    • Working tools / cleaning
      • Gun for sealing compounds
      • Filling knife
      • Manual and compressed air gun, scraper, adhesive tape

    • Storage / shelf life
      • Store frost-free and cool / protect for moisture / close containers
      • Shelf-life 12 months
      • If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.

        Special product variants (colour) 6 months.

        Observe the information on the container.

    • Usage
      • Approx. 100 ml/running metre for a 1 cm² joint cross-section

    • General information
      • Under certain conditions, silicone sealants in general tend to exhibit colour alterations (yellowing). The main factors responsible are:

        - contact with coatings based on alkyd resins or linseed oil

        - contact with resins or terpenes contained in wood

        - contact with unsuitable detergents

        - dark rooms

        - exposure to tobacco smoke

        - contact with substances containing bitumen or tar.

         

        Current regulations and legal requirements must be taken into account and deviations from these must be agreed separately.

        The relevant test certificates must be observed when planning and carrying out work.

    • Disposal instructions
      • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.

    • Safety / regulations
      • For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.

    Systemproducts