Article No. 343820

    Induline UV-LW-781/20

    Water-based, translucent, UV-curing intermediate & finishing coat for spray application

    Variant
    Induline UV-LW-781/20 matt
    Colour: clear | 3438
    Colour: clear | 3438
    Please choose a colour
    Size / Quantity

    Product specifications

    On delivery

    Binder Special UV-curing PU/acrylate copolymers
    Density (20°C) Approx. 1.04 g/cm³
    Odour Characteristic
    Degree of gloss Matt
    Viscosity Approx. 1800 mPas

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • For use indoors and outdoors
    • for dimensionally stable elements
    • For professional users only
    • For use on interior and exterior wood
    • Soft and hard woods
    • Dimensionally stable wood building elements: e.g. windows and doors
    • Protected constructions: e.g. wood-aluminium windows
    • Intermediate and finishing coats

    Properties

    • Water-based
    • Good flow properties
    • UV-curing: very quick handling
    • Highly resistant to temporary water stains
    • Very good hail resistance: elasticity at low temperatures
    • Special combination of binding agents creates an extremely hard-wearing surface
    • Preparation
      • Substrate requirements

        The substrate must be clean, dry, free of dust, grease and loose substances, and prepared in the correct manner.

        Dimensionally stable wood building elements: wood moisture content 11-15%

      • Preparations

        If necessary, impregnate non-resistant woods with a wood preservative* (*Use biocides safely. Always read the label and product information before use).

        Prime wood surfaces.

        If necessary, protect parapet joints with Induline V-Joint Protection or Induline AF-920.

    • Application
      • Temperature of the material, air and substrate: from min. +15 °C to max. +30 °C
      • Stir before use
      • Airless/airmix spraying
      • The values given are based on undiluted material. The best spraying pattern is achieved if the material has a temperature of 15-20 °C.

        Airless spraying: nozzle size: 0.28-0.33 mm; material pressure: 70-90 bar.

        Air-mix spraying: nozzle size: 0.28-0.33 mm; material pressure: 70-90 bar, atomiser air pressure 1-2 bar.

        Apply further coatings after drying and UV curing

        Seal opened containers well and use contents as soon as possible.

    • Application instructions
      • UV curing: Ga + Hg 1000 mJ / m²
      • Drying time: can be worked over after 4 h
      • Check colour, adhesion and compatibility with the substrate by setting up a trial area.

        Before coating technically modified woods and wood-based materials, apply the coating to a trial surface and conduct a suitability test on the desired area of use.

        Ensure good ventilation.

        Do not use in direct sunlight or at temperatures below +15 °C or above +30 °C.

        Substances in oak may bleed, causing dark discolouration, when coated with water dilutable dispersion stains.

        Sealing compounds must be compatible with the coating and may only be applied once the coating has dried thoroughly.

        The product is not self-crosslinking and must be cured using a suitable UV lamp

        Only use sealing profiles that are free of plasticisers.

        The specifications of VFF Code of Practice HO.03 must be observed with regard to the permitted dry layer thicknesses.

        Observe current standards and guidelines for coating wood building elements outdoors (Codes of Practice issued by the German Association of Window and Facade Manufacturers (VFF), Code of Practice No. 18 issued by the German Federal Committee for Paint and the Protection of Material Assets (BFS), guidelines issued by the German Lacquer and Printing Ink Association (VdL) and ift guidelines issued by the Institut für Fenstertechnik).

      • Drying

        Preliminary physical drying:
        UV curing: after approx. 4 hours (at 23 °C and 50% RH)
        UV curing after forced drying: 20 minutes flash-off zone (at approx. 20 °C and 65 - 75% RH) / 45 minutes drying phase (approx. 45 °C; 1 m/s air circulation)

        UV-crosslinking:
        Lamp type: Ga+Hg
        Lamp power: 80 - 120 watt/cm²
        Crosslinking energy values:
        500 - 1000 mJ/cm²
        Distance between object and lamp: 20 - 30 cm
        These parameters are guide values. Precise parameters are determined on a customer-specific basis.

        Ready for sanding and overcoating: after 10 minutes cooling phase

      • Thinning

        Ready to use

    • Working tools / cleaning
      • Airless/airmix spraying
      • Manual spray gun, automatic spraying equipment

      • Clean tools with water or Aqua RK-898 Cleaning Concentrate immediately after use.

        Ensure that any residue from cleaning is disposed of correctly.

    • Storage / shelf life
      • Store frost-free and cool / protect for moisture / close containers
      • Shelf-life 12 months
      • If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.

        Always close the container and protect the contents from sunlight.

    • Usage
      • Approx. 125 ml - 175 ml / m² per layer applied
      • 125 - 175 ml/m² per coat (plus spraying loss)
        (equivalent to a wet film thickness of 125 - 175 μm and a dry film thickness of 40 - 60 μm)

    • General information
      • Care and maintenance:

        Wood is subjected to great climatic and environmental stresses when outdoors. The coat is susceptible to the processes of natural ageing, wear and decomposition. Decomposition takes place at different speeds, depending on the stress (weak, average, strong) placed on the wood building element. Weathering stages may vary according to the part or element affected. To give wood the longest and best possible protection it is advisable to examine surfaces every year. Any damage found should be addressed immediately after cleaning.

        For cleaning and care, we recommend the care set for windows (2745) and doors (2746).

        Touch-up coat with Aqua HSL-35 and Aqua DSL-55.

        Observe current standards and guidelines for coating wood building elements outdoors (Codes of Practice issued by the German Association of Window and Facade Manufacturers (VFF), Code of Practice No. 18 issued by the German Federal Committee for Paint and the Protection of Material Assets (BFS), guidelines issued by the German Lacquer and Printing Ink Association (VdL) and ift guidelines issued by the Institut für Fenstertechnik).

    • Disposal instructions
      • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.

    • Safety / regulations
      • For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.