Article No. 087010
Single-component, solvent-free, polymer-modified bituminous thick coating with rubber granulate fillers

Product specifications
On delivery
(20 °C/70% relative humidity) Approx. 48 hours
The stated values represent typical product characteristics and are not to be construed as binding product specifications.
Field of application
- Waterproofing of new and old buildings with ground contact
- Water effect classes W1.1-E, W1.2-E, W2.1-E, W3-E and W4-E according to DIN 18533
- Retrofit waterproofing of buildings according to WTA Code of Practice 4-6
- Waterproofing of foundations and base points
Properties
- Solvent-free
- Water pressure tight
- Highly resistant to pressure > 0.3 MN/m²
- Highly flexible, elastic and crack-bridging
- Radon-tight (verified through testing)
-
Preparation
-
Substrate requirements
Even-surfaced, mineral substrate.
Clean, dust-free and capable of supporting a load.
Prepare concrete substrates at wall/base transition areas by means of mechanical material removal.
Matt damp surfaces are permitted.
If necessary, provide damp proofing.
-
Preparations
Remove projecting seams and mortar remains.
Break off or slope corners and edges.
Smooth out inner corners using a suitable mineral mortar.
Close indentations > 5 mm using a suitable mineral material.
Prime absorbent mineral substrates with Kiesol MB. Prime non-absorbent mineral substrates with BIT Primer [basic] (1:10 in water).
If the substrate requires reinforcement (restoration), prime using Kiesol (1:1 with water).
Create a scratch coat using the product as a contact layer and in order to prevent blisters.
-
-
Application
-
Application requirements
Temperature of the material, air and substrate: from min. +5 °C to max. +35 °C.
-
Ready to use, straight from the container.
Remove any dried material adhering to the edge of the bucket.
Apply the product in two layers on the previously prepared substrate.
If a reinforcement fabric is required, embed into the first waterproofing layer.
-
Application instructions
-
In the case of liquid-applied waterproofing materials, direct sunlight and/or wind exposure can cause accelerated skin formation and accompanying blistering.
Do not apply any further sealing layers until the previous layer has hardened sufficiently.
Protect freshly coated surfaces from rain, direct sunlight, frost and condensation.
Protect dry sealant from mechanical damage and UV radiation.
Please contact Remmers Technical Service (phone +49 5432 83900) before applying with machine processing.
-
-
Working tools / cleaning
-
Ladle, smoothing trowel, finishing scraper, suitable spraying equipment
-
Clean tools immediately after use with water.
Remove dried-on material using V 101 Thinner (0978).
-
Storage / shelf life
-
If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.
-
Usage
-
Approx. 1.4 kg/m²/mm dry film thickness See application rate table under Application Examples for details
-
Application examples
-
Film thickness margin according to DIN 18533Water exposure classes
(DIN 18533)Exposure class
(DIN 18195)withdrawn as of July 2017
Dry film thickness
(mm)Wet film thickness
(mm)Application quantity
(kg/m²)Yield 25 kg
(m²)W1-E
Soil moisture and non-pressing waterLoad case 4
Soil moisture and non-pressing water≥ 3 approx. 4.1 approx. 4.0 approx. 6.3 W2.1-E
Moderate exposure to pressing water (anchoring depth ≤ 3m)Load case 6
Standing seepage water and pressing water≥ 4 approx. 5.5 approx. 5.5 approx. 4.5 W3-E
Non-pressing water on soil-covered ceilingLoad case 5
Non-pressing water on soil-covered ceiling≥ 4 approx. 5.5 approx. 5.5 approx. 4.5 W4-E
Splashing water at wall plinth and capillary water in and underneath walls in contact with the groundPlinth waterproofing in wall positioning area ≥ 3 approx. 4.1 approx. 4.0 approx. 6.3 du = scratch coat, application rate approx. 0.8 kg/m² (depending on the substrate)
dv = - not necessary with finishing scraper
- without finishing scraper: application rate approx. 0.6 kg/m² (dmin = 4mm)
-
-
General information
-
Deviations from applicable regulations must be agreed separately.
The relevant test certificates must be observed when planning and carrying out work.
The special agreements as well as test certificates can be downloaded online at www.remmers.com.
-
-
Disposal instructions
-
Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.
-
-
Safety / regulations
-
For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.
-