Article No. 495301

    Diagnosekoffer für Mauerwerkssanierung

    Variant
    4953 | Diagnosekoffer für Mauerwerkssanierung
    Size / Quantity

    Product specifications

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • Determining salt type and concentration
    • Basic equipment for sampling

    Properties

    • Indicator reagents:
      1 pc each of MQuantTM sulphate, nitrate and chloride test, 100 pcs FisherbrandTM colour-fixed pH indicator strips, 1 bottle natural (L+) tartaric acid
    • Application
      • Conducting the measurement
        - Take an analysis strip from the tube, then re-close the tube immediately. Do not touch the test fields with your fingers.
        - Submerge all the test fields on the analysis strip in the prepared analysis solution for approx. 1 second.
        - After waiting for 1 minute, compare the colours on the analysis strip (test fields) with the colours on the label. Read off the salt concentrations in g/l.
        - Convert the recorded value in g/l into the corresponding salt concentration [% by mass]. To do this, use the table provided in the application examples section.

    • Application instructions
      • Distilled water is required for preparing samples. Please pour distilled water water into the 250 ml spray bottle before using the diagnostic kit.

        Different building materials must be analysed separately. We therefore recommend that building material samples are collected separately for subsequent analysis according to type (render, brickwork mortar, stone, etc.).

        The following water-soluble salts are normally tested: chlorides, sulphates and nitrates. The test strips required for these are included in the kit.

         

         

        Sample preparation
        Using the hammer, break up and pulverise the separate building material samples as finely and as free from impurities as possible.

        Weighing the samples
        Using the spoon scale, weigh out 10 g of the building material sample. Pour the pulverised sample material into a wide-necked glass bottle.

        Quick guide to the spoon scale
        - always use on a flat surface!
        - Do not use any solvent-based materials!
        - Weighing range up to 300 g
        - Switches off automatically after 1 minute when not in use
        (To switch on: ON/Tare button, weighing unit: gram or oz can be set by pressing the ∑/Unit button for 3 seconds, to switch off: press the ON/Tare button for 3 seconds.)

         

        Sample preparation
        - Use the plastic syringe to take up 50 ml of distilled water and slowly add it to the sample in the wide-necked glass bottle.
        - Shake vigorously.
        - Using the metal weighing scoop, add tartaric acid in portions until a pH value of 5 is set. To do this, shake vigorously after each addition of tartatic acid then use a pH test strip to check the pH value.

         

        Accuracy/reproducibility
        The accuracy of the results depends on the following parameters:
        - 10 g weighed-in quantity
        - 50 ml distilled water (quantity by volume)
        - pH value 5 (tartaric acid crystals completely dissolved)

         

        The results obtained provide valuable indications as to the condition of the examined building material and the stresses on it. However, they do not replace a professional material analysis in a chemical laboratory and do not comply with any standards. Further investigations, either in the laboratory and/or by specialist planners, may be conducted through Remmers GmbH or the Bernhard Remmers Institute of Analytics.

    • General information
      • General
        Weathering processes and the presence of moisture and salt in the surroudning soil lead to increasing moisture loss in building materials, up to destruction of the rock structure, which breaks down into its mineral components or rock fragments. In addition to natural weathering, accelerating influences on the construction site include the influence of the urban atmosphere, which contains airborne pollution (SO2, Nox), the creation of different material combinations (e.g. stone – joint mortar), and the particular microclimatic effects dictated by the shape of the building structure.

         

        Salt weathering
        The presence of salt and salt-containing solutions in the pore structure of building materials can cause severe damage over time. The damage mechanisms are:

        Linear growth pressure: When salt crystallises out from oversaturated solutions, it grows against the pore walls and exerts pressure.

        Hydration pressure: Depending on the environmental conditions (temperature, relative humidity), harmful salts are present in different "hydrate stages". This means that, depending on the humidity and temperature conditions, the "water of crystallisation" accumulates in the crystal lattice or is released from it. This is associated with significant volume changes, which in turn exert pressure on the pore walls in zones containing large amounts of salt. Readily soluble salts, e.g. alkaline and alkaline earth sulphates, chlorides and nitrates, are therefore especially dangerous.

        Hygroscopic effect of salts: In combination with the damage pattern of salt loads, the "hygroscopic" effect of many salts is also important. It is based on the principle that, even at ambient humidity levels of well below 100% RH, salt wants to absorb water from the air and dissolve in it.